Diamond Point International
 
MEN Mikro

MEN Mikro M97

Universal Counter M-Module

1 channel with 2 input lines, -40 to +85°C screened versions

 
M78
 
  • 1 channel with 2 input lines
  • 100-MHz counter technology
  • 32 bits resolution (9½ digits)
  • 10 ns @ ±1 LSB
  • Quartz oscillator better than 1 ppM
  • Variable conversion
  • 6 measuring functions
  • 0..100MHz, HV input: ±300V, LV input: ±10V
  • Input voltages over 60 V DC and 42 V AC (EN60950)
  • 20 mV sensitivity
  • Programmable switching points and hysteresis
  • Optical isolation
  • -40 to +85°C screened versions
  • ROHS compliant



Datasheet/Manual:

MEN M97 datasheet in PDF format Datasheet in PDF format
Manual available on request Manual available on request

 

Introduction

The M97 is based on the M-Module™ ANSI mezzanine standard. It can be used as an I/O extension in any type of bus system, i.e. CPCI, VME or on any type of stand-alone SBC. Appropriate M-Module™ carrier cards in 3U, 6U and other formats are available from MEN or other manufacturers.

The M97 is a universal counter that is perfectly suited for automated testing systems. Its extremely accurate time base together with the 100-MHz counter technology guarantee the highest precision. The switching points and hysteresis of the input signals can be programmed in a broad range. Optical isolation permits usage of the M-Module™ even in critical applications.

 
 

Specification

Basic Features:

100-MHz counter technology
32 bits resolution (9 1/2 digits)
6 measuring functions
Programmable switching points and hysteresis

Measurement Functions:

Frequency (line A)
High time
Low time
Period
Totalize (line A) during external gate (line B)
Time difference (line A to B)

Input Characteristics (A to B input):

2 input lines

  • 2 high-voltage inputs for ±300V
  • 2 coax inputs for ±10V

Input voltage range

  • ±10V peak-to-peak, input impedance 100 kOhm, frequency AC: 10Hz..100MHz, DC: 0..100MHz
  • ±300V peak-to-peak, input impedance 2 MOhm, frequency AC: 10Hz..100kHz, DC: 0..100kHz; fully usable only if requirements of EN60950 are fulfilled through additional safety measures (see user manual)

Maximum input voltage if no further safety measures are taken: 60V DC / 42V AC
Sensitivity: programmable in steps of

  • 5.37mV @ ±10V
  • 164mV @ ±300V

Minimum pulse duration: 10ns
Input noise: < 100μV typ.
Coupling: AC or DC (programmable)

Frequency A:

Resolution: measuring time 10ns @ ±1 LSB
Measuring times: programmable in steps of 1ms

High time, Low time, Period:

Range: 42s
Resolution: 10ns @ ±1LSB

Totalize:

Gate by line B
Maximum pulse duration: 42s
Resolution: 10ns @ ±1LSB
Gate error ±10ns

Time Difference:

Maximum time difference: 42s
Resolution: 10ns @ ±2LSB

Time Base:

Frequency: 1kHz, based on 100MHz system clock
Time range: 1ms..32.767s
Resolution: 1ms @ ±10ns

Peripheral Connections:

Via front panel on a 5-pin DBM 5W5S D-Sub connector with two high-voltage contacts and two coax contacts by FCT
Via carrier board using 24-pin connector (rear I/O)

M-Module™ Characteristics:

A08, D16, INTA, IDENT

Electrical:

Isolation voltage (inputs): 500V DC
Absolute maximum input voltages:

  • High-voltage contacts: 500V (only with additional safety measures according to EN60950)
  • Coax contacts: 20V

Supply voltage/power consumption: +5V (4.85V..5.25V), 750mA

Mechanical:

Dimensions: conforming to M-Module™ Standard
Weight: 120g

Environmental:

Temperature range (operation):

  • 0 to +60°C or -40 to +85°C
  • Airflow: min. 10m³/h

Temperature range (storage): -40 to +85°C
Relative humidity range (operation): max. 95% non-condensing
Relative humidity range (storage): max. 95% non-condensing
Altitude: -300m to + 3,000m
Shock: 15g/11ms
Bump: 10g/16ms
Vibration (sinusoidal): 2g/10 to 150Hz
Conformal coating on request

MTBF:

MTBF: tbd. @ 50°C (derived from MIL-HDBK-217F)

Safety:

THE M97 DOES NOT COMPLY WITH THE REQUIREMENTS OF THE EN60950 STANDARD. THE MAXIMUM INPUT VOLTAGES ARE 60V DC AND 42V AC. HOWEVER, THE M97 WAS DESIGNED TO PROVIDE HIGH-VOLTAGE FUNCTIONALITY. IF YOU NEED TO APPLY VOLTAGES HIGHER THAN 60V DC AND 42V AC, TAKE APPROPRIATE MEASURES TO KEEP THE SAFETY REQUIREMENTS OF EN60950.
PCB manufactured with a flammability rating of 94V-0 by UL recognized manufacturers

EMC:

Tested according to EN 55022 (radio disturbance), IEC1000-4-2 (ESD) and IEC1000-4-4 (burst)

Software Support:

MEN Driver Interface System (MDIS™ for Windows®, Linux, VxWorks®, QNX®, OS-9®)

ROHS Status:

This product is lead free/ROHS compliant.


Ordering Details:

Board:

04M097-00 Universal counter, closed metal housing, 0 to+60°C
04M097-03 Universal counter, open metal housing, -40 to +85°C screened

Accessories:

05M000-17 25 mounting screw sets to fix M-Modules on carrier boards

Further Information: