MEN Mikro M97Universal Counter M-Module1 channel with 2 input lines, -40 to +85°C screened versions |
![]() |
Datasheet/Manual:
|
|
IntroductionThe M97 is based on the M-Module™ ANSI mezzanine standard. It can be used as an I/O extension in any type of bus system, i.e. CPCI, VME or on any type of stand-alone SBC. Appropriate M-Module™ carrier cards in 3U, 6U and other formats are available from MEN or other manufacturers. The M97 is a universal counter that is perfectly suited for automated testing systems. Its extremely accurate time base together with the 100-MHz counter technology guarantee the highest precision. The switching points and hysteresis of the input signals can be programmed in a broad range. Optical isolation permits usage of the M-Module™ even in critical applications. |
Specification |
|
Basic Features: |
100-MHz counter technology |
Measurement Functions: |
Frequency (line A) |
Input Characteristics (A to B input): |
2 input lines
Input voltage range
Maximum input voltage if no further safety measures are
taken: 60V DC / 42V AC
Minimum pulse duration: 10ns |
Frequency A: |
Resolution: measuring time 10ns @ ±1 LSB |
High time, Low time, Period: |
Range: 42s |
Totalize: |
Gate by line B |
Time Difference: |
Maximum time difference: 42s |
Time Base: |
Frequency: 1kHz, based on 100MHz system clock |
Peripheral Connections: |
Via front panel on a 5-pin DBM 5W5S D-Sub connector with
two high-voltage contacts and two coax contacts by FCT |
M-Module™ Characteristics: |
A08, D16, INTA, IDENT |
Electrical: |
Isolation voltage (inputs): 500V DC
Supply voltage/power consumption: +5V (4.85V..5.25V), 750mA |
Mechanical: |
Dimensions: conforming to M-Module™ Standard |
Environmental: |
Temperature range (operation):
Temperature range (storage): -40 to +85°C |
MTBF: |
MTBF: tbd. @ 50°C (derived from MIL-HDBK-217F) |
Safety: |
THE M97 DOES NOT COMPLY WITH THE REQUIREMENTS OF THE EN60950 STANDARD. THE MAXIMUM INPUT VOLTAGES ARE 60V DC AND 42V AC. HOWEVER, THE M97 WAS DESIGNED TO PROVIDE HIGH-VOLTAGE FUNCTIONALITY. IF YOU NEED TO APPLY VOLTAGES HIGHER THAN 60V DC AND 42V AC, TAKE APPROPRIATE MEASURES TO KEEP THE SAFETY REQUIREMENTS OF EN60950. |
EMC: |
Tested according to EN 55022 (radio disturbance), IEC1000-4-2 (ESD) and IEC1000-4-4 (burst) |
Software Support: |
MEN Driver Interface System (MDIS™ for Windows®, Linux,
VxWorks®, QNX®, OS-9®) |
ROHS Status: |
This product is lead free/ROHS compliant. |
| Ordering Details: | |
Board: |
04M097-00 Universal counter, closed metal housing, 0 to+60°C |
Accessories: |
05M000-17 25 mounting screw sets to fix M-Modules on carrier boards |
Further Information: |
Want further information or pricing on this product? Either fill out our feedback form or contact us for further information. |
© 2013 Diamond Point International. All rights reserved. |